A new facility was presented which can expediently and cheaply measure the transient moisture content profile in multi-layer porous building envelope.Then,a common multi-layer porous building envelope was provided,which was constructed by cement mortar-red brick-cement plaster.With this kind of building envelope installed in the south wall,a well-controlled air-conditioning room was set up in Changsha,which is one of typical zones of hot and humid climate in China.And experiments were carried out to investigate the temperature and moisture distribution in multi-layer building envelope in summer,both in sunny day and rainy day.The results show that,the temperature and humidity at the interface between the brick and cement mortar are seriously affected by the changes of outdoor temperature and humidity,and the relative humidity at this interface keeps more than 80% for a long-term,which can easily trigger the growth of mould.The temperature and humidity at the interface between the brick and cement plaster change a little,and they are affected by the changes of indoor temperature and humidity.The temperature and humidity at the interface of the wall whose interior surface is affixed with a foam plastic wallpaper are generally higher than those of the wall without wallpaper.The heat transfer and moisture transfer in the envelope are coupled strongly.
A modified one-dimensional transient hygrothermal model for multilayer wall was proposed using air humidity ratio and temperature as the driving potentials.The solution for the governing equations was obtained numerically by implementing the finite-difference scheme.To evaluate the accuracy of the model,a test system was built up to measure relative humidity and temperature within a porous wall and compare with the prediction of the model.The prediction results have good agreement with the experimental results.For the interface close to indoor side,the maximum deviation of temperature between calculated and test data is 1.87 K,and the average deviation is 0.95 K;the maximum deviation of relative humidity is 11.4%,and the average deviation is 5.7%.For the interface close to outdoor side,the maximum deviation of temperature between prediction and measurement is 1.78 K,and the average deviation is 1.1 K;the maximum deviation of relative humidity is 9.9%,and the average deviation is 4.2%.