Based on the statistical characteristics of energy spectrum and the features of spectrum-shifting in spectrometry,the parameter adjustment method of Gaussian function space was applied in the simulation of spectrum-shifting.The transient characteristics of energy spectrum were described by the Gaussian function space,and then the Gaussian function space was transferred by parameter adjustment method.Furthermore,the spectrum-shifting in measurement of energy spectrum was simulated.The applied example shows that the parameters can be adjusted flexibly by this method to meet the various requirements in simulation of energy spectrum-shifting.This method was one parameterized simulation method with good performance for the practical application.
To obtain a quantitative understanding of the influence of temperature on the performance of multi-gap resistive plate chambers (MRPCs), we have tested the performance of a 10-gap, 12-pad, 2×2×12 cm2 active area MRPC at different temperatures with cosmic rays. Presented are results from measurements of high-voltage scans, noise rate, dark current, streamer, time resolution, count rate, charge spectrum, and detection efficiency. The test results show that the MRPC performance is significantly affected by temperature arising from the temperature- dependence of the glass resistivity.